View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-0BB86DB90205490C9B95C952CB94EF94 Perform maintenance on one Trane Gas fired furnace: power down Equipment at arrival Open blower and furnace cabinet doors Open burner cabinet door Removed all burner jets, Flame sensor, and hot surface igniter Vacuum and dusted out lots of debris from burner section of furnace Cleaned burners with Stainless steel brush and brushed and vacuumed clean Cleaned flame sensor with copper bristle brush Inspected hot service igniter- Showing minimum aware Vacuumed out all leaves and debris from fresh air intake Reassemble burner section of furnace, installing all burners, Flame sensor and hot surface igniter back in place Customer just replaced the air filter two days ago- And brand new condition Vacuum and dusted out furnace cabinet and components, clean and clear Polished and inspected blower motor wheel and assembly Secured and inspected electrical wiring, Connections and all