View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-825A034EB9AC4048A35E9EF76C1F4449 Customer has no heating from dual zone Fujitsu ductless system: * At arrival, the indoor heads are displaying error messages 7 economy and 9 led- * This indicates a communication failure between the indoor and outdoor equipment or possible failures with the condensing fan motor or PCB board * The indoor air filters were checked- The filters were dirty- Washed clean and reinstalled * Check outdoor condensing unit and all flare fittings- okay * reset the condenser at outdoor disconnect to clear the error message and connect gauges to condenser * call for heating from both Remotes once the fault is cleared- Both indoor heads and outdoor condenser are on and running * Monitor refrigerant pressures and temperatures on system- okay * Cycle system on and off from remote remotes at both indoor heads- Normal operations * System is turning on and off properly with no errors or fau