View visual findings from this job here - https://visionshare.xoi.io/?id=XA-15F7-F62B8F80264D4FC3BB109A3B871C1B25 Return to address leaking humidifier and correct install issues: * Shut power down to the air handler at arrival * The humidifier water panel is removed from Inside the humidifier cabinet and the drain is shoved inside * The transformer needs to be wired into the system, Additional wires need to be ran, Old control needs to be removed and new control needs to be wired in and tested * Open up air handler cabinet doors to access electrical cabinet * Wire in and install step down transformer into electrical cabinet * Run new wire from humidistat to humidifier location * Wire in New humidistat at control and air handler and transformer- review all connections- okay * secured the drain line off the humidifier to the return duct work * removed the old humidifier control and wiring and air seal where the old control was * shut cold water supply to indirect tank and drain water