Alex W.

Alex W.


Job Checkin

I ran a 20 amp dedicated circuit from the right handed main electrical panel to outside then with UF cable i was the circuit next too existing lines outside where i supported it throughout the run. Then i cut a 2 gang old work box size hole and drilled outside where i then pushed the wires inside the office. I installed the 2 gang old work box then i installed 2 tamper resistant receptacles and a plate. I drilled a hole through the concrete to get inside the home where the electrical panels were and i landed the wires in the right hand electrical panel on circuit #5. I installed a 20 amp arc fault breaker I did discuses with the customer about how the panels have double tapped neutrals and how this could lead to potential overheating on the neutral bar. Also I recommended the outside circuit which is connected to the garage be changed to gfcis and we will line side all the gfcis so if one trips it doesn’t affect the rest of the circuit. Finally i mentioned with all the technology i