Alex W.

Alex W.


Job Checkin

I installed a whole home surge protector in the left handed panel. I installed a 2 pole 50 amp homeline breaker and labeled the circuit. I ran a 80 amp circuit from the left handed main electrical panel throughout the unfinished basement supporting it along the joists then i drill to outside in the garage then installed a junction box and ran seal tight along the wall to outside in the back of a customer supplied car charger i mounted on the side of the garage. Then i ran THHN from the junction box to the charger. I made all my splices and terminations then installed a 2 pole 100 amp homeline electrical breaker in the panel. I patched the holes and installed duct seal inside the wall to protect the inside the wall from water damage Vip membership