Genny G.

Genny G.


Job Checkin

Today’s visit was for power loss in bedroom. All of the devices and lights were not working in the first floor bedroom. The devices were original to the home in 1987. They were also backstabbed which the heat/friction of the electrical load running through the circuit causes the wire to loosen over time. The receptacle in the upstairs bedroom was also on that circuit and as soon as I pulled it out the wire came out of the device. All of the devices in the home should be replaced as this will continue to happen from every day wear and tear. Today’s work was we replaced all devices on broken circuit. Please see attached solution to get the rest of your home safe.