725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for columbus, oh


Map of Columbus OH
seth p.

seth p.


Job Checkin

2017 train air handler and heat pump installed in the attic with two zones servicing the master bedroom and second floor of Southeast Wing Upon arrival both zones were calling for cooling all dampers are open and air handler is running in cooling speed. No lockouts or water alarms on the third floor Outdoor unit defrost control board is flashing service code for hard lock out. Hard lockout requires low voltage power cycle for reset. After low voltage power cycle reset the system ran normal and in good condition with nearly perfect refrigerant pressures and temperatures. 270/11 subcooling and 109/19 superheat. Do run capacitor 370 volt power supply is within specs. Compressor peaked at 37 amps on startup but runs at 7.9 Condenser coil needs heavy water flush cleaning due to matting over but no fault could be found with the system today Visual inspection of *kids playroom" system. System is running and functioning normal with fan and cooling call from Honeywell wireless network inte