2024 Daikin heat pump running in great condition. AA210 filter in new condition. Visual inspection of indoor coil. Flush drain pan and drain trap. Run test unit in cooling charge mode from thermostat. Delta t of 19F with supply temp of 52F. Outdoor measurements made with Daikin D-Checker. Refrigerant pressures are within spec. Outdoor fan motor and compressor are operating within specs. Outdoor coils are in clean condition. System is operating properly, efficiently and ready for Summer.