Performed cooling maintenance on an 11yr old trane 16seer ac Filter is good Blower clean Drain clear Outdoor coil slightly dirty Capacitor failed, it is rated 40/7.5 it measured 0/7.5 Replaced capacitor Refrigerant charge specification is 8⁰ of subcooling, actual reading was 2⁰ Added 1lb of refrigerant and a dye/sealant Washed outdoor unit System is operating within factory specs at this time.

Performed cooling maintenance on an 11yr old trane 16seer ac
Filter is good
Blower clean
Drain clear
Outdoor coil slightly dirty
Capacitor failed, it is rated 40/7.5 it measured 0/7.5
Replaced capacitor
Refrigerant charge specification is 8⁰ of subcooling, actual reading was 2⁰
Added 1lb of refrigerant and a dye/sealant
Washed outdoor unit
System is operating within factory specs at this time.