Dammage assessment on air conditioner condenser unit outside on wall brackton 2022 Carrier 3 ton bumped by mechanical equipment large enough to shear off the wall bracket screws attaching the condenser to the wall bracket. Minor surface damage to the air conditioner should not affect any operation or efficiency of the equipment. The aluminum cooling fins smashed are in a non-functional location R410A refrigerant pressure is holding 84 PSI at 21°f outdoor temperature. Correct running temperatures and pressures cannot be verified until outdoor temps are 70° f Reattach original vibration dampeners with new larger sheet metal screws in the same exact location as originally installed. Unfortunately the wall brackets were attached to the wall too close to each other for this unit and proper weight distribution does not allow a perfectly parallel installation Recommend homeowner locate color matching paint or clear coat to prevent rust on the painted metal surface