AC compressor has shorted internally causing the disconnect fuse to blow. Compressor will need replaced along with 45/7.5 capacitor, filter drier, and approximately 9lbs of new R410A refrigerant. Compressor parts warranty expired in 2020 and is no longer active. Recommend getting a quote for AC replacement to compare costs, and pros/cons of replacement.

AC compressor has shorted internally causing the disconnect fuse to blow. Compressor will need replaced along with 45/7.5 capacitor, filter drier, and approximately 9lbs of new R410A refrigerant. Compressor parts warranty expired in 2020 and is no longer active. 

Recommend getting a quote for AC replacement to compare costs, and pros/cons of replacement.