Job Checkin

Upon arrival today the system was already reset and running in heat mode and homeowner stated her husband reset the service code but that Cody still requested a safety inspection. 1998 Lennox two stage 80% system is running in fair to good condition considering the age. Homeowners description of the service codes over the the phone were red on solid green flashing. The only combination of this description states hard lock out rollout switch. Homeowner did not reset any manual push button rollout switches to get the system running. However if the colors were reversed the code indicates primary temperature limit overheat condition. Overheating conditions are automatic reset and could possibly run with a high voltage power cycle to reset the lockout in the control board. 4-in media filter is in new condition today, system was already running upon arrival and during test run of two stages the plenum temperature reached 140 stabilized in second stage heating. 65 temperature rises on the