Rob  S.

Rob S.


Job Checkin

Arrived to poor heating in home and room imbalance Identified failed outdoor piston, diagnostics photos attached. System is operating 15-20* below normal operating temperature causing system to go in to defrost more frequently, reducing capacity and once outdoor temps get so low it’s causing the system to lockout on low pressure. Supplemental heat is operating at a higher rate than designed causing high energy bills. System requires dampers and duct modification to properly balance the home. Back bedrooms are receiving to much air with other rooms receiving very little air. Homeowner request quote to repair outdoor unit and request a comfort specialist to resolve airflow/comfort issues.