Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed AC maintenance.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed DCM also added Ss2 switch to furnace.


Rob  S.

Rob S. Job Checkin

Arrived to inspect for water under unit Encapsulation material under air handler was dry. Toweled off around the unit to remove any existing water marks for future inspection. Checked drain and 90% flue vents for leaks. None identified but glued connections to be sure.


Rob  S.

Rob S. Job Checkin

DCM1 complete; Heat; (1) F16251 replaced. System is fully functional. All components are operating within manufacturers specifications. Gas pressure and temperature rise are within design tolerances. Heat checklist attached.


Rob  S.

Rob S. Job Checkin

DCM1 complete; Heat; (1) F16251 replaced. System is fully functional. All components are operating within manufacturers specifications. Gas pressure and temperature rise are within design parameters. Heat checklist attached


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Upon arrival went to indoor unit. Found condensation pump full of water and alarm triggered. Condensation pump was not pumping however system was still running. Condensation pump and safety had failed. Replaced condensation pump and wired in safety’s. Pump was not level, leveled pump and tested pump. Condensation pump is operating properly at this, system is cooling. Vacuumed up water in crawl space. Photos attached.


Rob  S.

Rob S. Job Checkin

DCM1 complete; AC; (1) F16251 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached.


Rob  S.

Rob S. Job Checkin

DCM1 complete; AC; (1) F16251 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached. Replaced indoor blower motor Mar 26, adjusted new motors cooling fan speed from Hi to M-Low


Rob  S.

Rob S. Job Checkin

Disconnected low and high voltage from fan motor. Removed existing fan housing and indoor blower motor. Separated blower motor from fan housing. Vacuumed loose dog hairs and cleaned off light dust found on the fan blades. Assembled new blower motor and fan housing, installed components into the furnace. Connected high and low voltage to the fan motor and tested system. System functions as designed in cool, heat, fan modes Trane EMC Motor Price is for Labor only,part is under warranty Dobbs Club Member 2 Year Part and Labor Non Club Member 1 Year Part and Labor Commercial 1 Year Part and Labor


Rob  S.

Rob S. Job Checkin

Arrived to continuous fan operation with no call present. Indoor blower motor is an ECM constant torque style motor Removed “G” wire from furnace control board, fan continued operation. Removed all low-voltage speed taps from ECM module, fan continued operation. Fan control module has failed on a closed circuit, fan operates continuously Speed modulates properly when call for heat or cool. Will have to replace ECM blower motor to correct the fault.


Rob  S.

Rob S. Job Checkin

DCM1 complete; Heat; (1) F16251 replaced. System is fully functional. All components are operating within manufacture specifications. Gas pressure and temperature rise are within design parameters. Heat checklist attached.


Rob  S.

Rob S. Job Checkin

DCM2 Complete; Heat; (1) F16251 replaced. System is fully functional. All components are operating within manufacture specifications. Gas pressure and temperature riser within design parameters. Heat checklist attached.


Rob  S.

Rob S. Job Checkin

DCM1 complete; AC; (1) F16251 replaced. System is fully functional. All components are operating within manufacturer specifications with exception. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions. AC checklist attached. Outdoor capacitor, fan, slightly low on capacitance.