11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Job Locations
for bronxville, ny


Map of Bronxville NY
Lorenzo M.

Lorenzo M.


Job Checkin

No charge as a courtesy Upon arrival spoke with customer who’s explaining that his issue is with valve on steam boiler being closed and emergency switch being off. Customer spoke with someone who directed him to open valves and turned system back on. Customer opened manual bypassed on steam boiler that over filled boiler and radiators causing radiators to leak. Drained water down with customer. Remove 6-10 gallon of 5gal water bucket to drop water pressure. Ran and monitored boiler for a hour. Tested automatic water feeder and automatic water shut off. Boiler is operating normally @ this time. System began to heat up customer was advised to watch and monitor boiler to see if x2 radiator still leak when system is running normally. Boiler was left operating @ this time.