View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-9FAE89DB6D0A4225A7BD7B8F4F9B8DBC Customer states that the first floor living room Daikin ductless split is not working properly I will not turn on in heat mode: At arrival, the indoor system is on and running. Check condenser and confirm that the outdoor condenser is on and running. Check indoor airflow and temperature splits and confirm system is working properly in heat mode- No errors * Shut system down at remote * Check indoor evaporator coil- Clean * Check indoor air filters- Slightly dirty washed, clean, and reinstalled * Test system operations- Cycle system on and off multiple times * Both the indoor and outdoor condenser are responding to calls from the remote each and every time- Normal operations * The customer is here to see that both the condensing unit and indoor blower or on and running and temperature splits from the unit 115 + degrees * No error codes at indoor or outdoor equipment * The