View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-685C8F04606D4A18AC58EFBD0BE28EBC Return to replace igniter on Navien gas water boiler that serves (2) hydro heating zones and indirect storage tank for DHW: shut power to boiler removed boiler cover door disconnected electrical wiring from igniter and flame rod assembly removed existing igniter and flame rod from boiler as well as gasket installed brand new igniter and flame rod with new gaskets inside boiler and secure in place install and secure electrical wiring and ground to igniter assembly review all connections before returning power to boiler once power is restored- indirect tank is calling for heat and boiler fires- circulator pump is on and running- normal operations smooth ignition- okay monitor operations until indirect tank is satisfied and system is back on stand by repair is made, system is tested and operational