11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Job Locations
for white plains, ny


Map of White Plains NY
will@innovativeairsolutions.com

will@innovativeairsolutions.com


Job Checkin

(1) TCC AC Maintenance - 410A - TRANE - Tested high and low voltage components ok, checked return grille and replaced 14x24x1 Filter provided by client, checked squirrel cage fan noticed blower wheel is extremely dusty and has heavy signs of growth build up. Blower must be removed and cleaned. Highly recommended for us to return for blower wheel cleaning ASAP. Checked evaporator coils and cleaned with evaporator spray and water. Tested primary drain pan with water multiple times no leakage at this time, tested condensation pump with water pump is operational no leakage at this time, cleaned out EZ Trap Safety with brush also cleaned Primary Pan, Drain is flowing freely with no blockage, Checked Condenser pressures, checked condenser coils ok. Sprayed and washed off condenser with hose. Checked electrical compartment and cleaned, tested compressor amps and blower amps, System is currently fully operational and cooling well at this time, Spoke to client about life expectancy of Air Condi