View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-2B5A149593FE4798A84908459077E2DA Customer is having an Intermittent issue with gas fire water boiler: customer has been resetting system to get heat back up and going: * at arrival the boiler has been reset and is working properly * with the customer, we cycled the boiler on and off 20+ times From the switch and the thermostat testing system operation- all is normal with no faults * The system cycles on and off multiple times on temperature and with demand calls from thermostats with no failures * While checking system notice that the boiler control, tea, stat, and circ Light get an intermittent flash and confirm with meter while recording video that the end which remains closed from the Argo panel * It is possible that there is an intermittent issue with the boiler control, which may be causing his failures * Unfortunately, with the system working at this time, we are unable to be certain of the findin