View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-8F99372B128A4C1AA71A157A9AF0DD46 Customer had a tree fall in the backyard of their home and take out a section of the house completely: Water was leaking out of the baseboard piping on the side of the house, so the customer shut the water to the entire home. At arrival, all heating is off and water is shut to the house Identify the first floor heating zone at the boiler and shut the gate valves on the supply and return side of system The boiler pressure is showing zero- Open water back to the house at main- The house is filled back with water as well as the boiler, and there are no leaks. Boiler pressure is now reading back normal Return power to the boiler and call for heating on the only two zones that we are able to test at this time which is the second and third floor baseboard heating zones- The boiler fires, Circulator pump is on and running, Zone valves are responding properly and supply and retur