Job Checkin

Upon arrival wife showed location of thermostat and garage system. Filter clean free of debris. When looking at the blower motor could see debris build up inside the wheel. Inspected coil found it clean free of debris on top half slight debris on underside of coil no leaks were detected on the coil. When looking at the outdoor unit found coil clean free of debris system had frost rings around the coil. Inspected the 35 capacitor found it failed reading 21.67. When checking charge on system found it slightly under manufacture specifications. With outdoor temperature 29 degrees moisture from the coil frost as system operating. Customer declined options at this time to discuss with husband.