Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by the customer and was led to the inside of the cottage. Temperature on the evaporator coil is set at 73 degrees and is only giving 70.1 and 70.3 in various locations inside cottage at this time. Found that the. Outage has cold spots throughout. Cleaned washable filter and removed from wall unit and took I outside and cleaned at this time. Inspected blower motor and wheel and they are functioning properly at this time. Inspected wireless thermostat and it is functioning properly at this time. Wall unit is sitting level on the wall in the main room of the cottage. Inspected condensate drain and it is clear at this time. Inspected refrigerant lines and they are tight and neat to the side of the home at this time. Inspected leuver on wall unit and it is functioning properly at this time. Ins-e Ted fan motor and blade and it is functioning properly at this time. Inspected fan motor seals and it is tight and neat at this time. Inspected c


Jeremy S.

Jeremy S. Job Checkin

All wiring is tight and good condition. The coils are clean. I rinsed the condenser coil. The batteries were bad in the remote. The batteries were replaced. Tested operation. The remote is working in all functions. The system is working properly in cooling and heating. The customer is considering having the heat pump in the main house be inspected. I prepared options and an updated maintenance program for two systems. She’s going to review it but declined at this time.


Trey M.

Trey M. Job Checkin

upon arrival customer stated to me that every time the system cuts on the next day, they have to reset the circuit breaker, because the system won’t work. I then went through the entire system and found that the system was giving off a error code of E7 which was DC fan motor fault I then made my way to the outdoor unit and found with the help of Ryan that the fan motor was not giving the proper ohms per manufacturer specifications. We came to the conclusion that the system has a bad condenser fan motor. I was unable to check anything else out on the system because it is non-operational , all coils looked clean at this time. Still need to clean filters when we come back. Customer is unsure if they wanna go with repairs or replacement. I have Adam coming out to him tomorrow to talk to them about replacement. Customer also stated that this is not the only problem they have had with this system. I told them that there could be a problem with other components on the system that will occur


Shawn H.

Shawn H. Job Checkin

# arrived at customers home was greeted by customer. Went to cottage to investigate system stopped working and found that the system was operational when I arrived stress to machine turn up the coolant heat to try to mimic what the customer described that the machine was doing was unsuccessful. Inspected coils looking for leaks possibility of shorts in electrical system found none at this time. Check voltage coming in from the disconnect and from the disconnect inside the house from the breaker panel found no issues at this time. Check refrigerant charge on system I think it’s a possibility it may be low on refrigerant was not low on refrigerant was within range. Inspected refrigerant lines connections to the heat pump outside found no leaks or issues at this time. As of the moment right now system is operational and operating normally at this time. Also customer was mentioned the fact of system always shutting off breaker main breaker to system tried to find it see if the breaker w


Ryan G.

Ryan G. Job Checkin

met with customer went to mini split found system run but found fan in high speed turned to auto and checked delta t was 18.5 checked charge on mini split suction was 150psi it is cooling but was not dehumidifieing found drain pan had water standing in it found drain was not clogged had not the greatest fall on the outside due to the sun baking it and causing it to flex and put a belly in the pipe got permission to make repair to drain line made repair and started system back up all is working good at this time,


Jeremy S.

Jeremy S. Job Checkin

Arrived and the customer stated they wanted their system cleaned. I made an estimate and received permission. We cleaned the blower wheel and housing. Brushed the small amount of debris from the condenser coil. Refrigerant temperatures are in correct range per manufacturer specifications. The system is moving more air and cooler air. The compressor is working properly at this time. The condenser fan is working properly at this time. The system is working properly at this time. The customer signed up for our club membership.