450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for haywood, va


Map of Haywood VA
chrisw@lovingairinc.com

chrisw@lovingairinc.com


Job Checkin

Performed cooling maintenance on one heat pump system. Inspected blower assembly and evaporator coil for cleanliness. Evaporator was slightly dirty. Cleaned evaporator coil per maintenance contract. Both are now clean and free of debris. Blower motor is currently amping within range of manufacture specifications at 0.6. Electrical connections, high and low voltage, are tight with no broken, melted or frayed wires. Cleared eztrap and confirmed drainage. Manually tested condensate pump to confirm it’s operation. Filter is in and clean. Thermostat is operating properly. Checked over the heat pump side of the equipment. Condenser coil is clean and free of debris. Condenser fan motor is currently amping within range of manufacture specifications at 0.9. Compressor is also amping within range of manufacture specifications at 5.6. Electrical connections outside, high and low voltage, are tight with no broken, melted or frayed wires. Contactor has slight char but is not pitted. Refrigerant