. Upon arrival filter was clean. Set the thermostat to to ac. Went to indoor unit. The coil is clean. The blower housing is clean. The blower motor amped within the manufacture specifications at .89. The drain is clear and all drain safeties are working properly. Inspected low and high voltage wiring. All wiring is good and tight. All duct work is good and tight. Went to outdoor unit. The Refrigerant pressures were 133/310. 10 degrees Subcooling. The Refrigerant pressures are within the range per manufacture specifications. All wiring is good and tight. The compressor and condenser fan motor amped within the manufacture specifications. The disconnect is working properly. The surge protector is good and working properly. The system is working properly. Went into stat and made sure there was no updates. The system is up to date. No issues found at this time.