450 Nelms Cir Unit 103
Fredericksburg, VA 22406
(540) 361-6744

Job Locations
for sumerduck, va


Map of Sumerduck VA
Cameron S.

Cameron S.


Job Checkin

A/c not going below 68 deg Basement furnace / evap coil Inspected blower and evap coil all clean free of debris, inspected blower amps 2.3 in range per manufacturer specs, inspected electrical wiring and connections none found burned are broken at this time, leak searched evap coil found no leaks, inspected filter was dirty pulled out inspected condensation drain blow out and tested all okay at this time, indoor working well at this time, inspected and tested t-stat all working good, Basement heat pump Inspected condenser coil all clean free of debris, inspected electrical wiring and connections none found burned are broken at this time, inspected contactor in good shape no pitting inspected capacitor it is in range per manufacturer specs, checked charge found system alittle low put 6 oz r410a in and checked super heat and subcooling, 9 deg of super heat and 8 deg of subcooling this is what the manufacturer wanted system dropped from 71 to 69 in 30 mins system is working well