Jack W.

Jack W.


Job Checkin

Heat pump furnace and AC cleaning: delta t was 20 and heat rise was 58 degrees. Air filter system was dirty So I told customer and he said he will Clean it. Air movement system was dirty so I cleaned off using proper cleaner and wipes. Evap coil was clean and clear but I wiped down with proper Cleaner.all wiring was clean and secure. Drain line system was clean and clear of all debris. Voltage enhancement system was running at 43.7/4.8uf. Factory spec is a 45/5uf. Voltage gateway system was clean and clear of all debris and signs of concern or worry. Compressor was running within good megohms. Cleaned off inside and outside of indoor and outdoor unit. Systems were up and running at normal operation at the end of the visit.