Matthew  F.

Matthew F.


Job Checkin

Club heat pump rejuvenation, Supply has a temperature of 112 degrees. Return has a temperature of 71 degrees. Heat rise of 41 degrees. Factory spec heat rise of between 35-65 degrees. The air filter is clean. All of the indoor control board connections are secure. Pulled out and cleaned off the blower wheel fins. The blower wheel is clean and spins freely without any obstructions. Cleaned out ez trap with the provided brush. Checked evaporator coil and pan both are clean and looking good. The condensate pump ran while servicing the unit. Wd40 wipe down of the indoor unit. The outdoor voltage enhancement system is reading 42.8/4.9uf and with a factory spec of 45/5uf it is within the allowable fault. The electrical gateway is without any pitting or burn marks and looks good. Tighten up loose electrical connections on the outdoor voltage enhancement system. All of the outdoor control board connections are secure. Brushed off the outdoor electrical compartment. The outdoor coil as well as