Performed club rejuvenation cleaning air movement blower wheel is clean free of any obstruction. Air movement has variable speed ECM. Coil is good. Voltage gateway is good all wiring is tight. Heat strips are good functioning as intended. PCB control has no signs of concerns all wiring connectors and harness are tight and secured . 16X20X1 filter is clean filter is a merv11 heat rise of 44 degrees. Refrigerant Pumping System RLA factory specs 10.9amp actual 5.74amps Air movement system factory specs 0.97amps actual 0.64amps voltage enhancement system factory specs 35/5uf actual 34/4.86uf. All wiring is tight and secured system is functioning as intended at this time.