Jack W.

Jack W. Job Checkin

Furmace rejuvination: heat rise was 71. Air filter system was dirty so I changed out with customers extras. Air movement system was clean but I tried to wipe anything off but nothing came off. All wiring was clean and secure. Drain line was clean and clear.Flame gateway and sensor system both look great and were running fine. Evap coil was clean and clear of all debris. Heat movement system was clean and clear of all debris and signs of concern or worry. Static pressure readings were good. Cleaned off inside and outside of outdoor unit with proper cleaner and wipes. System was up and running at normal operation at the end of the visit.


Tammy A.

Tammy A. Job Checkin

customer signing back up for club plan with amanda


Blake B.

Blake B. Job Checkin

Club ac rejuvenation, 20 delta t, checked air filter customer recently changed it, checked blower wheel spinning with no restrictions and clean, voltage enhancement system 14.27fp 15 factory, let customer know it will need replaced soon. No other issues Outdoor unit, voltage enhancement system 65.8fp 70 factory 4.8fp 5 fan factory, opened up unit and vacuumed leaves and dirt out of it. Coils were clean, checked all board connections. No other issues.


Clay K.

Clay K. Job Checkin

Club renewal


Clay K.

Clay K. Job Checkin

System service, test ran system, voltage enhancement system factory spec 70, actual 69.9, compressor run load amps factory spec 21.8, actual 11.6, outdoor fan full load amps factory spec 2.8, actual 1.1, start up amps 24.3, installed compressor saver system and now start up amps 8.4, delta t 18, operation normal at this time.


Greg H.

Greg H. Job Checkin

Ac club service getting a 18 degree delta t. Filter is clean. Checked condesate drain and did not detect any clogs. Checked uv light and it is still working. Tighten all screws and eletrical connections. Checked blower, evaporator, and pan all are clean. Checked blower voltage enhancement system and it read within factory spec of 15uf. Checked duct work and there is no debris. Checked outdoor system coil is clean Voltage enhancement system read within factory spec. Voltage gateway haves no pitting. Operation normal at this time


Clay K.

Clay K. Job Checkin

Not a call back during installation power wire for thermostat was Nick at the terminal board for the furnace and finally broke repaired that wire and checked all others operation normal at this time.


Clay K.

Clay K. Job Checkin

Club service Heating checked manifold gas pressure 3.3 in WC clean air ranger screen air ranger filter clean operation normal at this time.


Clay K.

Clay K. Job Checkin

No heat, system control blank, checked equipment and found that the low voltage protection system had failed due to a shorted power supply cord for the electrostatic filter, installed replacement protestion system and also new power cord, test ran. \


Paul N.

Paul N. Job Checkin

16 SEER 5 Ton AC


Steven P.

Steven P. Job Checkin

Installing new Amana 16 SEER 5 Ton AC with Honeywell Lyric wifi thermostat and 10 year parts, 10 year labor, and lifetime unit replacement warranty


Gerald T.

Gerald T. Job Checkin

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim


Gerald T.

Gerald T. Job Checkin

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim


Gerald T.

Gerald T. Job Checkin

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim


Gerald T.

Gerald T. Job Checkin

Nine-year-old furnace, indoor coil, and outdoor coil. Indoor dry bulb was 66. The system immediately started (fan) upon arrival. However, the cool supply air was 66 degrees and the return was also 66. The air filter was new. The indoor coil was only a little dirty but found numerous refrigerant leaks with the electronic refrigerant leak detector. Outside the refrigerant pumping system's run amps were zero. Tested the voltage enhancer and it was at 0 uF. Replaced the voltage enhancer with the tenant's permission. Thereafter the refrigerant pumping system's run amps were 10 (FLA is 20), the start amps were 6.5, and the air exhaust system's amps were .65 (FLA is 1.5). All normal after the repairs. The supply temp fell to 58, but the liquid pressure was 205 and the liquid line temp was 68 for a SC of two. The vapor pressure was 70 and the vapor line temp was 63 for a SH of 49. These readings indicate the system is low on refrigerant due to several leaks on the indoor coil. Sending an estim