2017 water furnace 5 series equipment is running in excellent condition and ready for the winter heating season Single pump non-pressurized variable speed flow center is programmed for 30% minimum and 40% maximum and currently flowing 9 GPM on high speed HP heating mode. Glycol antifreeze is confirmed at +18° Confirm operation of 10KW electric auxiliary heat strips with 39.9 amps at 240 volts Confirm K9 DHW relay operation and pump motor circulation in test mode Power flush condensate drain trap vinyl tubing and visually inspect condensate drain pump 20x25x5 air bear filter was replaced in April and still appears to be in like new condition AID computer scan confirms correct logging with E99 * 9 system resets and 0 logged trouble codes All equipment is clean safe and ready for heating mode