Service recall Furnace locked out on ignition attempts Blocked drain pressure switch no closing Port on collector box had water in it Drain is off the left side of the collector box Moved pressure switch to the left side port. Blew out drain again as additional precaution Furnace operating normally at this time Took pictures and measurements for system replacement quote

Service recall
Furnace locked out on ignition attempts
Blocked drain pressure switch no closing
Port on collector box had water in it
Drain is off the left side of the collector box
Moved pressure switch to the left side port.
Blew out drain again as additional precaution
Furnace operating normally at this time

Took pictures and measurements for system replacement quote