NEED TO RETURN TO SERVICE MITSUBISHI DUCTLESS HP NEED TO PERFORM ROUTINE MAINTENANCE ON X2 INDOOR HEAD NEED TO PERFORM DEEP CLEANING AND REJUVENATION ON X1 INDOOR HEAD( KITCHEN/LIVING ROOM ZONE) Performed AC maintenance on x1 R-22 conventional system. 6’ ladder needed to access attic. Need to return to perform maintenance on x2/3 ductless indoor head. Recommending deep cleaning and rejuvenation on x1 of 3 Ductless indoor head(Kitchen/Living room zone) Chemically clean evaporator coil Chemically treat pans with slow release tabs and gel treatment Flush condensate pans and drain lines Replace standard 14x30x1 provided by customer Visually inspected ductwork for leakage and breaks Clean return grill on second floor Inspect thermostat operation Inspect blower motor and housing for dirt and debris Inspect and test safety switches Inspect and test condensate pump Inspect and test electrical connections Tighten and secure low voltage controls and connections Check temperature split @ equipm