View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EE1C-1A14209213354735972B8619113BC5C8 Preform maintenance on x1 Carrier infinity gas fired furnace with bypass humidifier: 6ft ladder needed to access system through x2 ceiling hatch’s open furnace cabinet doors shut power to system removed flame sensor and hot surface igniter- cleaned sensor with copper bristle brush and polished clean with steel wool inspected hot surface igniter- okay brushed out and cleaned burner jet, furnace cabinet and components inspected PVC fresh air and exhaust: okay secured all electrical wiring and connections in furnace and blower cabinet inspected blower motor/ wheel and assembly removed condensate trap- flushed clean and primed with fresh water removed neutralizer kit- inspected minerals- minimal ware- flushed clean washed condensate trap and all tubing reinstalled neutralizer kit back into system drainage and tested- okay replaced and dated air filter and humidifier water pan