View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-38BC50E705064C07828BC11F07228E5A Customer has no heat in the Entire home : * At arrival confirmed that the nest thermostat is calling for heating, but the furnace is not running * Check the furnace in the basement * This is a Lennox furnace that is about to be 27 years old * The vent louver door on the burner section is Trying to open with a call for Heat, but slamming shut * The motor for the damper is hot and you can see broken plastic that is holding the damper door * When the damper door is manually held down the furnace tries to fire, but fails * The wire For the electronic spark igniter is broken and not making connection * After manipulating the wire, the furnace does fire, but once hand is removed from the damper door, the furnace shuts down * This is a 27-year-old gas furnace. That is well over its average life expectancy with multiple issues. * No repairs are recommended on the system * Shut