Conducted sewer video inspection at residential property in Hobart. Client reported recurring backups in basement fixtures despite multiple routine cleanings by previous service providers. Deployed high-definition sewer camera from basement cleanout access point. Line is 6-inch clay pipe transitioning to city connection at approximately 65 feet. Inspection revealed multiple issues: significant root intrusion at 18 feet and 43 feet from access point penetrating through pipe joints; partial collapse at 38 feet creating approximately 30% restriction in flow capacity; and improper grade between 50-60 feet creating standing water and debris accumulation. Notable mineral buildup observed throughout system indicating history of water treatment discharge. Total line length to city connection measured at 72 feet. Provided customer with comprehensive digital recording of inspection with professional narration identifying all deficiencies. Recommended trenchless pipe lining as most cost-effective