John R.

John R. Job Checkin

Cleaned and measured sewer in preparation for lining from 6” pvc clean out in front yard (7’5” deep) to city main. Also line from catch basin in back (7’5” deep) to overlap liner from clean out x5 reinstates Lined sewer from 6” pvc clean out 45’ to city main, also lined from catch basin 85’ to liner from clean out, reinstated 5 connection


Bob S.

Bob S. Job Checkin

Televised sewer from outside clean out approximately 41ft to city main and 70ft to catch basin near house. There were roots at many location going downstream and the first 8 ft going back to the house. Will provide a proposal for lining sewer to prevent roots from growing in.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. Both the concrete and the metal look to be in good condition. Will provide an estimate for spray lining the ducts to encapsulate the concrete.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are cardboard and are deteriorated with holes in the bottom. The floors would need to be opened in several locations if we were to try to restore these ducts. Suggest going overhead in bedroom and a mini split in family room.


Bob S.

Bob S. Job Checkin

Sewer leak detection service call. Televised sewer from overhead cleanout about 56ft to city main. Sewer has heavy roots near cast to clay. Will provide a proposal for installing a liner.


Bob S.

Bob S. Job Checkin

Sewer inspection service call. Email jcwinter14@gmail.com. Rodded sewer then televised. Can only get Rodded about 60ft. Located this area and it is under a storm basin in the street


Bob S.

Bob S. Job Checkin

Televised sewer from outside PVC Check valve. There are roots at the cast to clay. Rodded into house to clear roots. Provide proposal for lining from PVC by check valve back into cast iron.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely encapsulated and the air in the home will be safe for the customer to breathe.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. There was water in the ducts in the back section of the house. Property needs to be regarded back there as it is sloping to the house. The downspout should also be extended to reduce the amount of water accumulating next to the house. Once water issue is resolved the ducts should be spray lined with Duct Armor duct lining material to encapsulate the concrete asbestos ducts.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections. Ducts appear in solid condition only slight rusting on metal. Suggest spray lining with Duct Armor duct lining material to seal connections to help reduce the possibility of radon gas.


Jim D.

Jim D. Job Checkin

Sprayed underground transite air ducts with our duct lining material. Air ducts are completely encapsulated with a strong rubberized material.


Bob S.

Bob S. Job Checkin

Video inspection of underground air ducts. Ducts appear to be Transite Ducts containing asbestos with metal couplings and elbows. Suggest spray lining ducts with Duct Armor to encapsulate the ducts without having to dig and remove or turn system overhead.