Televised sewer from overhead clean out in basement approximately 35ft to flood control check valve. Clay tile looked in good condition with only slight offsets. Cast is scaled and has possible fine roots left over from a previous rodding but there did not appear to be any major shifts or shearing of the cast iron pipe before it got to the clay tile tee. The pit in the basement is holding water but homeowner had the pump oout saying the pump was not working. Suggest having Bills plumping replace the pump and get that working again. Will provide a quote for installing a short 4ft patch in the 4” cast iron to seal off roots.
Televised from outside clean out and also from clean out in crawl space but sewer was backed up. Rodded from outside clean out and was only able to get a straight cable through to open sewer and get level to drop. Retelevised again and found that clean out in crawl has a hole in side of pipe on riser and allowed stone and clay to enter the pipe. Could not get camer to pass by all the stone in the pipe from the crawl space clean out. Televised from clean out in closet in basement and see that the line has heavy roots in clay downstream of the connection for drain tile. The toilet in the addition is actually tied into the original drain tile in the house then connects to the main sewer at the cross connection. Suggest Bills plumbing install a clean out at cross and also use the open pipe and hole to jet and remove the stone in the line. After the clean outs are installed we can provide a proposal for installing a liner if requested by the homeowner. We will also provide a quote for ins
Ductwork video inspection service call. Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with asbestos. Will provide quote for spray lining to encapsulate the ducts.
Sewer repair service call. Lined 6” clay tile sewer line from outside cleanout approximately 68’ downstream ending just before city main.
Sewer repair service call. Televised sewer from flood control system in front yard approximately 50 ft to city main. Bolts need to be repaired in flood control system after lining of the sewer.
11-18-2022: lined sewer from outside clean out downstream 30’ towards city main, did not line to main, lined just past bad area near sidewalk/ curb where sink hole is present.
Televised sewer from outside clean out to city main. Sewer has some roots and slight cracks. Cast iron going into house is heavily scaled and was holding some paper but was able to break it up with the camera. Suggest lining clay descaling the cast and possibly epoxy brush coating the cast.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely encapsulated and the air in the home will be safe for the customer to breathe.
We are cleaning all of the underground asbestos transite air ducts with our special high powered vacuum. Once the air ducts are clean, we will encapsulate them with our rubberized duct lining material. The air in the home will now be safe for the customer to breathe.
Cleaned under slab ducts, using camera. Sealed areas where fine dst was entering system.
Did a video inspection of underground duct work.
Lined the sewer to stop ground water from leaking into the sewer line washing dirt away from under road causing a sink hole.
Televised sewer from outside clean out to city main. Found shift in tile near curb of street. A sink hole has formed in the street near sewer line. Giving customer a quote to line sewer to stop infiltration.