Televised ducts under slab floor. Ducts are concrete transite ducts. The ducts look in good condition and the metal fittings also look to be good with no rust. Will provide proposal for spray lining to encapsulate concrete pipes.
Cleaned sewer line from outside cleanout approximately 65’ downstream and approximately 10’ upstream. Flushed loose tree roots out of the sewer line. Installed a 5’ 6” patch over the void in the clay tile approximately 50’ downstream.
Under slab ductwork video inspection service visit. Televised ducts under slab portion of house. Ducts are galvanized and are rusting. Suggest spin cast mortaring then spray lining with Duct Armor duct lining material.
Under slab duct inspection service visit. Televised ducts under slab floor. Ducts are spiral wound ducts and showing signs of rust with sand in them. Suggest spin cast mortaring then spray lining to restore and seal the ducts.
Drain clog service call. 9-28-2023: Tv’d sewer from out side clean out in front yard. Retrieved broken 6” pvc cap from sewer lodged/ stuck in 6” clay pipe about 10’ downstream of 6” pvc clean out in front yard. Re-televised out to city main and back yo overhead stack line was clear both ways.
Air duct inspection service call. Televised ducts under slab floor. Ducts are spiral wound ducts that are showing signs of rust and possible mold. Suggest spin cast mortaring ducts to restore structure then spray lining with Duct Armor duct lining material to prevent mold and seal for radon.
Under slab ductwork video inspection service call. Televised ducts under slab floor. Ducts are spiral wound ducts and are showing heavy signs of rust. Suggest spin cast mortaring then spray lining with Duct Armor duct lining material.
Under slab ductwork video inspection service visit. Televised ducts under slab floor. Ducts are spiral wound galvanized ducts that are heavily rusted. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.
Televised ducts under slab floor. Ducts are spiral wound ducts that are rusted. Suggest spin casting ducts then spray lining with Duct Armr duct lining material.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite duct work.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Televised ducts under slab floor. Ducts are concrete ducts with asbestos. Propose to spray line ducts with Duct Armor duct lining material to encapsulate the concrete ducts.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.