Televised from 6” outside clean out in back of house approximately 125ft until the camera went under water and we could not push any further due to either roots or offset in pipe. City main sits approximately 12 ft further in middle of the street. Could not televise upstream back to house because the clean out swept downstream and could not turn camera back up to house. There is a 4” cast iron clean out next to house in the area of the radon system. Removed that cap and it also sweeps downstream. Suggest when construction in kitchen is being done and pipes under floor are exposed we can televise from there and also possibly from a pulled toilet.
Televised ducts under slab ducts. Ducts are concrete with metal fittings that are extremely rusted allowing stone to enter the system and cause blockages. Metal fittings would need to be spin cast mortared if necessary and possibly a few open holes to access pipes that are completely blocked
Televised ducts under slab floor. Ducts are galvanized and showing heavy signs of rust and deterioration. The duct in the first bedroom on the left is collapsed and has stone in it that will need to be cleared out. Suggest spin cast mortaring the spray lining with Duct Armor duct lining material.
Ductwork video inspection service visit. Televised ducts under slab portion of house in laundry room. Ducts are concrete and look to be in good condition. Will provide proposal for spray lining to encapsulate.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
We are applying our Trenchless Cast mortar to the heavily rusted plenum box under the furnace. The mortar will give the plenum box a new and strong structure and sand and debris will no longer enter the system from this area.
Televised ducts under slab floor. Ducts are concrete transite ducts. Suggest spray lining ducts with Duct Armor duct lining material to encapsulate the concrete ducts.
Lined 10’ of deteriorated 4” cast iron pipe going out of basement wall.
Applied second application of our duct lining material to underground air ducts. The air ducts are now completely sealed.
Televised under slab duct work, ducts were transite pipe with metal connections. Encapsulated ducts with Duct Armor.