Very nice people , gave me lots of options and variables. Seemed very trust worthy, would highly recommend…
Response from Trenchless Innovations Inc.:
Thank you, Bruno! We're delighted you appreciated our service options and trustworthiness. Your recommendation means a lot to us, and we remain committed to providing excellent customer experiences for all our clients.
Overall Experience
Quality
Price
Convenience
Televised sewer from two outside clean outs on east and west sides of house. The two lines connect to a main line in front of the house then travel to the city main at the edge of the parkway near the street. There is heavy roots in the main portion of the sewer. A clean out needs to be installed on that main run then Trenchless can install a liner from new clean out to city main.
10-14-2025: tvd and measured sewer in preparation for lining from 6” pvc clean out in alley (7’10” deep) downstream 70’ to city main, also line from clean out in backyard near fence (4’8”deep) 130’ downstream to clean out in alley. Reinstate clean out in alley after lining over. 10-22-2025: lined sewer from 6” pvc outside clean out in alley 76’ downstream to city main starting liner in 6” pvc downstream of clean out and ending in 6” clay just before city main, also lined from 6” pvc clean out in backyard 125’ downstream to pvc clean out in alley starting in 6” pvc near clean out in backyard and ending in 6” pvc near clean out in alley.
Televised sewer from clean outs outside in backyard and in front near sidewalk. Sewer has roots at several area and also has heavy sludge between clean outs. Downstream clean out is a combination clean out / check valve and we believe that is the reason for the sludge buildup. Water leaking on the floor appears like it may be coming from a crack on a tee above ground that was visible through the cleanout in the garage. Will provide proposal for lining clay to prevent roots.
Installed 4’x6” spot repair liner at at last joint at connection to city main where there was a hole in pipe just before city main.
Looked at site and measured for possible lining
Sewer video inspection service call. Televised from inside clean out to main through flood control system after check valve was moved out of the way. Section from the house to the flood control has bad pitch and a belly with roots at the base of the stack at the tee. From FC to main there are roots at many joints. Could not TV from catch basing back into house due to camera exiting hole by baffle. Will provide proposal for possibly lining
Provide estimate for installing patch liner over hole before city main
Televised ducts under slab portion of house. Ducts are cardboard ducts with metal connections. Suggest spin cast mortaring cardboard then spray lining system with Duct Armor.
12-7-2022: Installed three overlapping 8ft spot repair patch liners through the existing clean out in the basement floor, and position to cover over the area at the curb and parkway where the pipe is severely cracked.
We are applying the first application of our rubberized duct lining material to all of the underground cardboard air ducts.
We are applying our Trenchless Cast Mortar to all of the underground cardboard air ducts. The weak cardboard air ducts are now encased in our strong concrete like mortar and will no longer deteriorate in the future.
Televised ducts under slab floor. Ducts are clay tile ducts. There was no signs of water in the ducts at time of inspection. There were separated joints and some cracking in the pipes which could be contributing to the moisture in the house. The plenum bottom is also gravel. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.
We are cleaning all the underground and Encapsulating all the transite pipe with 2 coats of our duct lining material, leaving a safe and clean duct for air to travel through and into the home.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.