Televised ducts under slab floor. Ducts are concrete ducts showing slight signs of dirt in line with metal fittings only showing slight signs of rust. Will provide proposal for spray lining with Duct Armor duct lining material to encapsulate the concrete pipe.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete possibly Transite with metal fittings that are rusting. Suggest spin casting metal fittings then spray lining entire system with Duct Armor.


Bob S.

Bob S. Job Checkin

Under slab ductwork video inspection service call. Televised ducts under slab floor. Ducts are PVC ducts showing signs of possible mold. Suggest spray lining with Duct Armor.


Kevin W.

Kevin W. Job Checkin

Piping repair service call. Descaled 10’ of 4” cast, Installed spot repair liners 10’ in total using silicate resin from overhead stack clean out in basement, starting in 4” pvc ending in 6” pvc to cover over all 4” cast iron where there was a break near foundation wall.


Kevin W.

Kevin W. Job Checkin

We are doing a video inspection of the underground duct work which is pvc pipe with metal elbows.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are spiral wound metal and are showing signs of rust. Suggest spin cast mortaring then spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are pvc with metal tees that are rusting and allowing water into the ducts. Suggest spray lining with Duct Armor duct lining material. Also suggest installing an outside sump pit and pump.


Jim D.

Jim D. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the deteriorated underground duct work. The duct work will be completely sealed and mold and debris will no longer enter the system.


Kevin W.

Kevin W. Job Checkin

We are going to clean and restore all of the heavily rusted underground duct work. We are applying our Trenchless cast mortar to all of the heavily rusted elbows and connections in underground duct work. This will give them a strong structure and debris will not be able to enter from these areas. We are also going to apply the first of two applications of our rubberized duct lining material. This will completely seal the underground duct system.


Kevin W.

Kevin W. Job Checkin

We are inspecting the heavily deteriorated underground air ducts with our camera and looking for rusted areas and mold.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are spiral wound metal and showing signs of water and rust. Bathroom elbow is very rusted and deterating and needs to be spin cast mortared. Downspouts in back of entire building need to be run out and the concrete patios are all tilted back towards unit. After water issue is resolved the ducts should be spin cast mortared in two locations then spray line the entire system with Duct Armor duct lining material.


Jim D.

Jim D. Job Checkin

Encapsulated all deteriorated underground duct work with our rubberized duct lining material. The air in the home is now environmentally safe to breathe.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are galvanized metal and showing heavy signs of rust and deterioration. Suggest spin cast mortar and then spray lining with Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

Applied our trenchless cast to all the underground duct work that was heavily rusted and deteriorated to give the host pipe structure in preparation to seal with our duct lining product leaving a solid pipe, and a clean breathing environment.


Kevin W.

Kevin W. Job Checkin

Replaced crushed PVC duct lines with 8” galvanized metal air ducts.