Full system inspection for poor cooling performance. Evaporator coil inspection is normal blower speed is currently set to 3.5 t with a 3.0 cooling system. All indoor equipment appears to be in fair to good condition Outdoor air conditioner inspection discovered a 100% matted over and compacted condenser coil requiring partial disassembly for heavy duty water flush Cooling system performance inspection and refrigerant running pressure test post cleaning is in very good condition Refrigerant pressures are perfectly within the manufacturers stated specs During testing the smart thermostat installed by the previous owners had automatically reset to 80° and turned off the system. Homeowner is aware of the condition and says it has happened before but that is not the issue they are concerned with Blower fan speed is already set to 3.5 running with a 3.0 system. The blower speed can be turned up one more selection to 4.0 but is not recommended at this time until the performance of the