Jackhammer another 6’ concrete on inside of house, drill new penetration through foundation, redo drain down to septic tank, pump septic tank effluent into lift station, lower septic tank discharge line going to effluent tank, no replacement of concrete/flooring included. 2 year warranty Jackhammered slab in downstairs living room. Drilled through foundation wall and lowered pipe running out of house. Corrected pitch on pipe to septic tank. Dug up effluent discharge line and corrected pitch down to lift station. Installed new two way cleanout on line to septic tank and effluent line between septic tank and lift station for servicing. Bedded pipe inside the house but did not back. Customer had ESOG out to assess dirt settling under foundation that initially caused sewer back up. ESOG requested we not backfill holes inside the house as they are going to be pumping grout under the slab. Took video showing proper pitch of every section of the sewer line under the slab and notified homeown