Arrived today to clean outdoor condenser coil along with install armaflex on the suction line-set.Upon arrival water rinsed coil then chemically cleaned twice removing all debris/build up.Once finished cleaning equipment placed armaflex on suction line-set cutting to specific measurements.Once completed performing repairs tested equipment confirming the indoor & outdoor equipment was fully operational.Began diagnostic on the indoor equipment the filter 14x25x1 was extremely discolored along with clogged the filter was replaced on this visit due to remolding taking place recommend replacement of filters more frequently.Blower motor was fully operational not showing any signs of being intermittent or dropping out.Drain line was blew out & flushed confirming it was draining properly and not clogged.Tested flood prevention safeties confirming they were both operational.Zone equipment was confirmed to be operational along with having all necessary accessories.Once finished with diagnostic o