I’m sure the team serviced our systems perfectly. I would appreciate a detailed, verbal summary, helping me to know their findings (besides, everything is working well). That’s what made me love my experience with Keith. Thank you so much!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for doraville, ga

Dobbs Technician A.

Dobbs Technician A. Job Checkin

Performed a two system cooling maintenance on a two AirTemp’s the ODT is 67°.Tested overall operation of equipment confirming the indoor & outdoor equipment was both fully operational.There are two 16x25x4 which were gently used with clogging beginning both filters were replaced on this visit.Blower motor was fully operational not showing any signs of being intermittent or dropping out.Blower wheel was inspected finding it to be dirty when a blower wheel gets dirty it minimizes the efficiency of equipment along with places a strain on equipment and parts which shortens the lifespan of both a quote has been provided to clean blower wheel.Inspected indoor evaporator coil finding it to be dirty when a indoor evaporator coil gets dirty it minimizes the efficiency of equipment along with can affect the ability to heat/cool properly a quote has been provided to clean indoor evaporator coil.Inspected wires along with connections not finding any broken, damaged or arced wires along with didn’t


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Replaced pressure switch, cycled unit, operating properly.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Replaced warranty control board. Furnace fired up and worked for about 10 minutes. Furnace cut off and showed pressure switch fault. By passed pressure switches and found back pressure switch with red dot bad. I have pressure switch bypassed and furnace is operational. Estimate included. Called R.E. Michael. Part under warranty.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Upstairs unit had a rollout switch tripped, reset and checked burners and temperature, alls good, possibly a weak rollout switch, if happens again it will need replaced. The main floor furnace located in basement has a bad control board, talked with R.E. Michael, part is warranty. Estimate is included for replacement.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Did cooling maintenance on2 systems, both operating properly