Dobbs Technician A.

Dobbs Technician A. Job Checkin

Upon arrival was getting code T024_Z, replaced sensor and tested in high cool let system run for 10mins. Codes have cleared and none popped up. System is operating as designed.


Keith D.

Keith D. Job Checkin

No one home - called Melissa and she said that she called the after hours line and left a message that they got called in


Christian R.

Christian R. Job Checkin

Installed 8” bypass damper. Ran all new zone testing to insure the bypass damper is operating correctly.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed heat maintenance, talked with rheem support, had to adjust CFM for zone 1 so furnace will operate. A bypass needs to be installed.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Started both units. Checked ac, adjusted Freon, we will need to return to check pressures again when weather warms. Started and checked both furnaces. Both drains properly nd delta t is good. Programmed both thermostats. Left both furnaces in heat at 60 degrees.


Christian R.

Christian R. Job Checkin

Installed gas lines with regulators to both furnaces. Vacuumed outdoor units to 500 microns and opened valves. Systems are ready for high voltage and start up.


Christian R.

Christian R. Job Checkin

Finished installing lineset and line hide. Installed outdoor unit. Things need to finish: Need to run gas lines Units need high voltage power Indoor units need receptacles to power condensate pumps Barb fitting for vinyl tubing Vacuum units Start up


Christian R.

Christian R. Job Checkin

Finished installing metal duct work. Installed flue vent. Got lineset ready for outdoor unit to be installed.


Christian R.

Christian R. Job Checkin

Started installing 2nd unit


Christian R.

Christian R. Job Checkin

Installed trunk line for 2nd unit


Rob  S.

Rob S. Job Checkin

Arrived to No Cool Identified burnt drive board. Some kind of snake or rodent got into the control panel and grounded/shorted out the board. Installed new drive board and tested system. Functions in low to mid cool during modulation as well as high cool DCM1 complete; AC; (1) F16251 replaced. System is fully functional. All components are operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor conditions.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Dropped off 2 A/C portables, homeowner asked if she could install them, told her how to do it and gave her tape. Checked outdoor unit for update.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Upon arrival saw thermostat code (A929_O 240V Missing or inverter comm failure). Went to outdoor unit tested voltage for disconnect, contactor and transformer received 240. Checked communication wires and wire nuts, checked continuity through communication wires. Checked molex plugs on drive board for voltage got 240. Checked molex plugs on control board and drive board to make sure they were secure. Turned off outdoor and indoor units for 15 mins to do a hard reset, turned back on checked thermostat still giving code from arrival, cleared fault on thermostat, fault immediately came back. Homeowner wants a portable until drive board gets replaced, told her I could do it tomorrow afternoon.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Removed old equipment and installed new carrier package unit a/c with electric heat. Installed fresh air damper and new thermostat. Reconnected high voltage, low voltage and drain line. Tested system operations in heating and cooling.


Keith D.

Keith D. Job Checkin

Set up ladder for measurement of curb adapter