DCM1 complete; Heat; (1) F18201 replaced. System is functional and heating. Components are operational but outside of manufactures tolerances Outdoor contactor is pitted but still operational. Failure would result in no cool and reduced heating capacity Outdoor capacitor is a 45 + 5 and currently operating at 39.6 + 2.5. Capacitor is still capable of starting unit but has increased amperage and if failure occurs would result in no cool and reduced capacity to heat Indoor capacitor is 10 and currently operating at 6.8. Capacitor is still capable of starting blower but has increased amperage. If failure occurs would result in no heat or cool System is slightly overcharged System has no water safeties Open estimate is available from previous visit