11 Kimball Place
Mount Vernon, NY 10550
914-793-7700

Job Locations
for pelham manor, ny


Map of Pelham Manor NY
Mark E.

Mark E.


Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-AF62C9614D9A4BF2BA5BD44155FE2500 Customer has no heat in the master bedroom for the radiant heating: * Check boiler at arrival- Systems are on and running and second floor radiant heat pump is on and running * Found the boiler pressure low on both system * The backflow preventer is dripping water from the factory gaskets * When trying to feed the water into the boiler- The feeder was stuck open and water constantly filling the system- Feeder was shut down * Systems are equipped with low water cut off * Check the radiant manifold in the master bedroom closet- The zone actuators are opening, but no water is flowing * In the past Gary and myself had reviewed the system and determined that and it’s current state that it is unable to properly purge and bleed the system * The customer was curious about possibly getting the air heating up and running: All zones are closed in the basement * Up in the attic pipin