View visual findings from this job here - https://visionshare.xoi.io/?id=XA-DE27-33675B2AB54B47789ED4402BDE9C5EEB Return trip to replace pressure transducer-sensor on gas fired forced air furnace: * power down equipment at arrival * open system cabinet doors * disconnected electrical wiring harness, going to existing pressure transducer * Remove existing pressure transducer from furnace * Installed and secured brand new pressure transducer in furnace * Secure electrical wire harness to new pressure transducer * After reviewing all connections, return power back to the furnace * Call for heating at the nest thermostat and test system operations: The inducer motor turns on, The pressure and limit switches close, Igniter blows up gas valve opens, and furnace fires- Blower motor is on and running normal operations * Cycle furnace on and off three times- Normal operations, no errors * Monitor system operations for 15 minutes- okay * System is back up and running, Repair is made in system