View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-0F7BCB5563874841A042FD214DCE15A5 The customer has no hot water: Customer states that he called babushka out last week to fix the heating problem- Since he was out last, he has had heat throughout the home, but no hot water. Arrival found the indirect tank set for 160°- But the circulator pump is not running- Confirmed that the aquastat is calling for domestic hot water, but no line voltage is going to the circulator pump. Found from last visit many changes on the boiler, Controls disconnected, Relays relocated, And wiring change changes. We were able to provide the customer with a tank of domestic hot water by switching the relay back to the domestic hot water side- But with the relay switching ensure that something else is going to be affected. With the cold temperatures, do not want to compromise any of his existing heating right now so return the relay back to where we found it. After speaking with ma